WhatsApp | +91 87603 34488
Automation Products | International Brands
prosensautomation@gmail.com

Allen Bradley brand 100-E16KJ10 IEC 16 A Contactor

0.00

• Panel mounting or mounting on 35 mm DIN
Rail
E09…E370
– AC/DC electronic coil with built-in surge
suppression
– optional PLC interface on E116…E370
E400…E2650
– AC/DC electronic coil with built-in surge
suppression and PLC interface
• Made of environmentally friendly materials

Description

Technical Specifications

Mechanical

Number of auxiliary contacts as normally open contact 1
Number of auxiliary contacts as normally closed contact 0
Vibration resistance IEC 60068-2-6
Shock resistance IEC 60068-2-27
Altitude, max 3000 m of installation site
Switching frequency, max 600 ops/hr, AC-1
Weight AC/DC (electronic): 0.43 kg (0.95 lbs.)
Protection class Contactor main contact: IP2X

Electrical

Voltage type for actuating AC/DC
Rated control supply voltage at AC 50 Hz 24 V
Rated control supply voltage at AC 60 Hz 24 V
Rated control supply voltage at DC 20 V
Type of electrical connection of main circuit Screw connection
Rated impulse voltage withstand (Uimp) 6 kV
Operating time, closing delay 40 ms
Operating time, opening delay 11 ms
Optional overload relays Electronic
Main current circuit resistance 0.36 mΩ
Rated isolation voltage (Ui) 690V per IEC
Function Non-reversing contactor
Standard coil, pick-up 50VA/50 W @ 24-60V AC, 20-60V DC
Standard coil, hold-in 2.2VA/2 W @ 24-60V AC, 20-60V DC
General purpose current (enclosed) 20 A @ 600V per UL/CSA
Power dissipation 1.2 W per pole at Ie, AC-1, 400V
Short time withstand (Icw) 3-pole: 80 A for 30 s (40 °C)
FLA 30 A @ 600V, 3-phase per UL/CSA HVAC applications
Rated operational current and power (enclosed) 5 Hp @ 220-240V, 3-phase per UL/CSA
LRA 180 A @ 440-480V, 3-phase AC per UL/CSA HVAC applications
Electromagnetic compatibility IEC 60947-1 – Environment A and B (100-E09…E38 only.)
Total power dissipation 3.05 W at Ie, AC-3, 400V, AC/DC control (120-250V)
Operating limits, dropout (≤0.60) x Us @ DC control
Rating for switching AC motors 3-poles: 9 kW @ 690V, AC-2, AC-3 (50 Hz)
Operating limits, pick-up (0.85…1.1) x Us @ 50/60 Hz
DIN fuses (gG) current rating Type 2 (per IEC 60947-4-1): 35 A @ 400 V, 100 kA available fault current
Rated voltage (Ue) 24, 48, 110, 220, 440V DC
Switching of lighting loads Tungsten lamps: 30 A @ 600V, 3-phase (break all lines) per UL/CSA
UL class RK5 fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60 A @ 600V, 5 kA available fault current
Rated operational current (Ie) 3-poles: 30 A @ 40 °C, AC-1 (690V)
UL class J and CSA HRCI-J fuses rating Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60 A @ 600V, 100 kA available fault current
UL inverse-time circuit breaker Type 1 Combination (per UL 60947 and CSA 22.2 No. 14): 60 A @ 600V, 10 kA available fault current
Switching of power transformers Apparent power: 9 kVA @ 208V, AC-6a, 60 Hz (n = 20)
Rated operational power (Pe) 9 kW @ 690V, AC-2, AC-3 switching of 3-phase motors (50 Hz), ambient temperature 60 °C (140 °F)
Switching of DC loads 3-poles in series: 30 A @ 220V (Shunt-wound motors-starting, reverse current breaking, reversing, stepping: DC-3 at 60 °C)
Optional accessories Side-or front-mount auxiliary contacts, Mechanical interlocks, Connecting bars
Features Panel mounting or mounting on 35 mm DIN rail, AC/DC electronic coil, Made of environmentally friendly materials
MCCB short circuit current rating Type 2 (per IEC 60947-4-1): 28 A @ 400 V, 70 kA available fault current

Environmental

Climatic withstand Category B according to IEC 60947-1, annex Q
Ambient temperature Storage: -60…80 °C (-76…176 °F)

Certification

Coil insulation class Class F per IEC 60947-4-1

Business Hours

Mon – Sat : 10 AM to 7 PM

For Quick Reply

Off – Business Hours – WhatsApp only