WhatsApp | +91 87603 34488
Automation Products | International Brands
prosensautomation@gmail.com

Leuze Brand SLS46CI-70.K28-M12 Single Beam Safety Device Transmitter

0.00

Part no.: 50121911

 

Additional information

Brand

Leuze

Type

Single Beam Safety Device Transmitter

Basic data

Series 46C

Functions

Activation input

Characteristic Parameters

Type 2, IEC/EN 61496, in combination with a suitable test monitoring unit, e.g. MSI-TR1B
SIL 1, IEC 61508, in combination with a suitable test monitoring unit, e.g. MSI-TR1B
SILCL 1, IEC/EN 62061, in combination with a suitable test monitoring unit, e.g. MSI-TR1B
Performance Level (PL) c, EN ISO 13849-1:2008, In combination with a suitable test monitoring unit, e.g. MSI-TR1B
MTTFd 400 years, EN ISO 13849-1
PFHD 3E-10 per hour
Mission time 20 years, EN ISO 13849-1
Category 2, EN ISO 13849, In combination with a suitable test monitoring unit, e.g. MSI-TR1B

Optical data

Operating range 5 … 70 m
Operating range limit 5 … 80 m
Light source LED, Infrared
Wavelength 940 nm
Transmitted-signal shape Pulsed
LED group 1
Opening angle, max. -5 … 5 °

Electrical data

Protective circuit Polarity reversal protection
Short circuit protected

Performanc edata

Supply voltage UB 24 V, DC, -20 … 20 %, Incl. residual ripple
Residual ripple 10 %, From UB
Open-circuit current 0 … 40 mA

Number of activation inputs

1 Piece(s)

Activation inputs

Active switching state High

Time behaviour

Switching frequency 250 Hz
Response time 2.5 ms
Readiness delay 300 ms

Connection

Number of connections 1 Piece(s)

Connection 1

Function Signal IN
Voltage supply
Type of connection Connector
Thread size M12
Material Plastic
No. of pins 4 -pin

Mechanical data

Design Cubic
Dimension (W x H x L) 20.5 mm x 76.3 mm x 44 mm
Housing material Plastic
Plastic housing PC-PBT
Lens cover material Plastic / PMMA
Net weight 50 g
Housing color Red
Type of fastening Through-hole mounting
Compatibility of materials ECOLAB

Operations and display

Type of display LED
Number of LEDs 2 Piece(s)

Environmental data

Ambient temperature, operation -30 … 60 °C
Ambient temperature, storage -30 … 70 °C

Certifications

Degree of protection IP 67
IP 69K
Protection class III, Rating voltage 50 V
Certifications TÜV Süd
c TÜV NRTL US
c UL US
Standards applied IEC 60947-5-2, IEC/EN 61496

Classification

Customs tariff number 85365019
ECLASS 5.1.4 27272701
ECLASS 8.0 27272701
ECLASS 9.0 27272701
ECLASS 10.0 27272701
ECLASS 12.0 27272701
ECLASS 13.0 27272701
ETIM 5.0 EC001831
ETIM 6.0 EC001831
ETIM 7.0 EC001831
ETIM 8.0 EC001831

Business Hours