WhatsApp | +91 87603 34488
Automation Products | International Brands
prosensautomation@gmail.com

Omron Brand LY4N DC24 Bi-Power Relays

0.00

Single stable, Single, Plug-in terminal, Operating indicator LED, Not equipped, 24 VDC 10 A, 110 VAC 10 A, Output 4PDT (24 VDC 10 A)

Coil ratings 24 VDC 69 mA
Operating indicator LED
Contact form 4PDT
Contact method Single
Contact material Ag alloy
Contact rated load 110 VAC 10 A (Resistive load)
110 VAC 7.5 A (Inductive load (cosφ = 0.4))
24 VDC 10 A (Resistive load)
24 VDC 5 A (Inductive load (L/R = 7 ms))
Terminal structure Plug-in terminal

Description

Ratings
Operating indicator LED
Degree of protection Closed type (cover)
Terminal structure Plug-in terminal
Coil Coil ratings 24 VDC 69 mA
Coil resistance 350 Ω
Operate voltage (Set voltage) 80% max.
Release voltage (Reset voltage) 10% min.
Maximum voltage 110%
Power consumption Approx. 1.5 W
Contact Contact rated load 110 VAC 10 A (Resistive load)
110 VAC 7.5 A (Inductive load (cosφ = 0.4))
24 VDC 10 A (Resistive load)
24 VDC 5 A (Inductive load (L/R = 7 ms))
Max. contact voltage 250 VAC
125 VDC
Max. contact current AC: 10 A
DC: 10 A
Contact form 4PDT
Contact method Single
Contact material Ag alloy
Performance
Contact resistance 50 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Reset time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Maximum operating frequency Mechanical: 18000 time/h
Rated load: 1800 time/h
Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 2000 VAC 50/60 Hz 1 min
Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min
Between contacts of different polarity: 2000 VAC 50/60 Hz 1 min
Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Shock resistance (destruction) 1000 m/s2
Shock resistance (Malfunction) 200 m/s2
Endurance (Mechanical) 100 million operations min. (switching frequency 18,000 operations/h)
Endurance (Electrical) 200,000 operations min. (23 ℃, switching frequency 1,800 operations/h)
Failure rate 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute)
Ambient temperature (Operating) -25 to 40 ℃ (with no freezing or condensation)
Ambient humidity (Operating) 5 to 85% RH
Weight Approx. 70 g
Mounting method Socket

Business Hours

Mon – Sat : 10 AM to 7 PM

For Quick Reply

Off – Business Hours – WhatsApp only