📍 201/1, Dr. Nanjappa road, Coimbatore, Tamil Nadu, India
Try: PRK5B, 50155803, retro-reflective, safety light curtain, M12 connector

Shridhan DLS series – Displacer Type Magnetic Level Switch | ProSens Automation

● In Stock

The Shridhan DLS Series comprises Displacer Type Magnetic Level Switches for liquid level alarm and control applications.

The DLS operates on the buoyancy principle, using suspended displacers and spring movement to actuate a magnetic switching mechanism as liquid level changes.

Designed for simple or complex applications including surging and agitated liquids, with configurations for large tanks, high temperature, high pressure and vacuum applications.

✅ Genuine Shridhan product with manufacturer warranty

✅ ProSens Automation — Coimbatore, Erode & Salem

Product Description

The Shridhan DLS Series Displacer Type Magnetic Level Switch provides a wide choice of alarm and control configurations for industrial liquid level applications.

The DLS works on a simple buoyancy principle. As the liquid level rises and progressively immerses the displacer elements, the effective weight suspended on the spring reduces. The resulting change in spring length produces magnet movement and operates the switching mechanism.

The DLS is designed for applications involving surging liquids, agitated fluids and other demanding level-control conditions. The brochure also specifies configurations suitable for large tanks up to 15 metres and customized arrangements for high-temperature, high-pressure and vacuum applications.

Built-in limit stops help prevent over-stroking under level surge conditions. The switch points can be adjusted at site, depending on the selected configuration.

Key Features

  • Displacer type magnetic level switch operating on the buoyancy principle
  • Wide choice of switching functions
  • Suitable for large tanks up to 15 metres
  • Site adjustable switch points
  • Suitable for turbulent liquids even without still pipes
  • Configurations for high-temperature, high-pressure and vacuum applications
  • Built-in limit stops to prevent over-stroking under level surge conditions
  • Weather-proof and Ex-proof enclosure options
  • Single, dual and multiple switch/displacer configurations
  • Internal direct, perforated still well and external chamber installation options
  • Suitable for narrow and wide differential level-control applications

How the DLS Series Works

The DLS uses a displacer that is heavier than the liquid and is suspended by a spring. When the liquid level rises and contacts the displacer, buoyancy reduces the effective suspended weight.

This causes the spring to retract slightly to a new equilibrium position. The spring movement causes the magnetic sleeve to move into the field of the external magnet, actuating the switching element.

The switching mechanism operates in a similar manner to the switching mechanism used in vertical float-operated level switches. :contentReference[oaicite:0]{index=0}

Component Function
Displacer Senses liquid level through buoyancy effect
Flexible Rope Suspends the displacer
Return Spring Changes effective spring length as liquid level changes
Magnetic Sleeve Transfers spring movement to the magnetic switching mechanism
Switch Mechanism Provides the electrical switching output
Limit Stops Helps prevent over-stroking during level surges

General Specifications

Parameter Specification
Enclosure Cast Aluminium, Weather Proof IP66; Cast Aluminium Ex-proof Gr. IIA & IIB or IIC
Conduit Connection Brass ¾" ET or ½" NPT
Measuring Range 500 mm ~ 15000 mm
Operating Differential 40 ± 5 mm / Adjustable / 65 ± 5 mm
Switch Type Micro switch
Switch Contacts 2 SPDT (2 NO + 2 NC) @ 5A, 230 VAC (Resistive)
Switch Action Bistable
Terminals To suit 1.5 mm² conduit
Flexible Rope SS304, SS316, PP, PTFE
Displacer SS304, SS316, PP, PTFE
Spring Housing SS316, PP / PTFE Insulation
Spring Material SS316, SS316L
Process Connection MS, SS304, SS316, PP (SS clad), PTFE (SS clad)
Flanged Process Connection MS, SS304, SS316, PP (65 NB)
Perforated Still Well MS, SS304, SS316, PP (80 NB)
External Cage MS, SS304, SS316, PP (80 NB)
Maximum Temperature 0–200°C without cooling fins; 0–300°C with cooling fins
Temperature Above 300°C Contact factory
Maximum Test Pressure Vacuum to 40 kg/cm²; contact factory for pressure above 40 kg/cm²
Minimum Specific Gravity 0.7; contact factory for specific gravity below 0.7

The above specifications are taken from the DLS general-specification table in the brochure. :contentReference[oaicite:1]{index=1}

Switch & Differential Configurations

The brochure describes both narrow-differential and wide-differential arrangements.

Configuration Description
Single Switch Models Narrow differential type instruments intended for level alarm applications.
Dual Switch Models Can provide different switching levels and wider differential control.
Wide Differential Factory calibrated with a choice of operating sequences.
Multiple Displacers Ordering options include One/One, Two/One, Two/Two, Three/Two and Three/Three switch/displacer arrangements.

For narrow differential instruments, the brochure specifies a differential band of approximately ±51 mm (2") in water, varying with liquid specific gravity. For wide differential units, the minimum differential band is approximately 152 mm (6") in water, with the maximum differential determined by the displacer suspension cable length. :contentReference[oaicite:2]{index=2}

Installation Options

Installation Description
Internal Direct Mounting Displacer assembly installed directly inside the tank.
Perforated Still Well Available in MS, SS304, SS316 and PP configurations.
External Chamber External chamber arrangement available with different material options.

Process Connection Options

Option Configuration
1 3" #150 ANSI Flange
2 80 NB, BS 10-E Flange
O Others

Displacer Material Options

Material Ordering Option
SS304 1
SS316 2
PP 3
Teflon 4
Others O

Applications

Application / Media Condition Suitability Mentioned in Brochure
Foaming liquids Suitable for level control applications
Surging liquids Suitable for level applications involving surging conditions
Agitated fluids Suitable for agitated liquid applications
Sewage handling Listed application
Dirty liquids Listed application
Paints Listed application
Liquids with solids Listed application

The brochure specifically identifies foaming or surging fluids, agitated fluids, sewage handling, dirty liquids, paints and liquids with solids as DLS applications. :contentReference[oaicite:3]{index=3}

Operating Sequences

The DLS Series can be configured for different pump-control and alarm sequences.

Sequence Operation Described in Brochure
Pump Control Plus Over-Flow Alarm Pump stops at high level and starts when the liquid falls to the low level. If the pump does not stop and the liquid reaches the high-high level, an alarm or shutdown provision can be provided.
Drain / Dry-Run Protection Alarm Pump stops at high level and starts when liquid falls to the low level. If the pump does not start and liquid reaches the low-low level, an alarm or additional pump-start command can be provided.

These operating sequences are illustrated in the DLS brochure under the pump-control and alarm section. :contentReference[oaicite:4]{index=4}

Ordering Information

The brochure specifies the DLS ordering structure as:

DLS 1 2 3 4 5 6 7

Example shown in the brochure:

DLS A A 2 G 1 1 N

1 — Switch Mechanisms / Displacers

Code Configuration
AOne / One
BTwo / One
CTwo / Two
DThree / Two
EThree / Three

2 — Enclosure

Code Configuration
ACast Aluminium, Weather Proof IP65 × ¾" ET
BCast Aluminium, Ex-proof IP66 Gr. IIA & IIB × ½" NPT
CCast Aluminium, Ex-proof IP66 Gr. IIC × ½" NPT
OOthers

3 — Displacer MOC

Code Material
1SS304
2SS316
3PP
4Teflon
OOthers

4 — Process Connection MOC

The brochure lists the process connection material options as MS, SS304, SS316, PP and Teflon configurations, with other options available.

5 — Process Connection

Code Configuration
13" #150 ANSI Flange
280 NB, BS 10-E Flange
OOthers

6 — Installation

Code Configuration
1Internal Direct
2Perforated Still Well in MS
3Perforated Still Well in SS304
4Perforated Still Well in SS316
5Perforated Still Well in PP
6External Chamber with 1" NB Flange in MS
7External Chamber with 1" NB Flange in SS304
8External Chamber with 1" NB Flange in SS316
9External Chamber with 1" NB Flange in PP
OOthers

7 — High Temperature Arrangement

Code Configuration
NNot provided
PProvided

The complete DLS ordering information is taken from the brochure's DLS ordering section. :contentReference[oaicite:5]{index=5}

Where DLS Series Is Used

Application DLS Application Context
Large Tanks Suitable for tanks up to 15 metres measuring range
Foaming Liquids Level detection and control
Surging Liquids Designed to handle level surge conditions
Agitated Fluids Level control in agitated vessels
Sewage Handling Liquid level monitoring and control
Dirty Liquids Level control in dirty-liquid applications
Paints Level detection and control
Liquids with Solids Level detection and control

What's in the Box

  • DLS Displacer Type Magnetic Level Switch as configured
  • Selected displacer and suspension arrangement
  • Selected enclosure and process connection
  • Installation arrangement, where specified
  • High-temperature arrangement, where specified

Note: Actual supplied configuration depends on the selected DLS ordering code.

Buy Shridhan DLS Series from ProSens Automation

The Shridhan DLS Series is available through ProSens Automation for industrial liquid level alarm and control applications.

For selecting the correct DLS configuration, share the liquid type, specific gravity, tank height, required level points, operating temperature, pressure, process connection and installation arrangement.

ProSens Automation — Coimbatore, Erode & Salem
Shipping available across India.

FAQ

What is the Shridhan DLS Series?

The DLS Series is a Displacer Type Magnetic Level Switch designed for liquid level alarm and control applications.

How does a DLS level switch work?

It works using buoyancy. As liquid progressively immerses the displacer, its effective suspended weight changes, causing spring movement that actuates the magnetic switching mechanism.

What tank size can the DLS Series handle?

The brochure specifies a measuring range of 500 mm to 15,000 mm and identifies suitability for large tanks up to 15 metres.

Can DLS be used with turbulent liquids?

Yes. The brochure specifically states that DLS provides reliable performance in turbulent liquids even without still pipes.

What is the minimum specific gravity?

The general specification lists a minimum specific gravity of 0.7. The brochure advises contacting the factory for specific gravity below 0.7.

What is the maximum temperature?

The specified range is 0–200°C without cooling fins and 0–300°C with cooling fins. The brochure advises contacting the factory for temperatures above 300°C.

Can DLS be used for high-pressure applications?

Yes. The general specification lists vacuum to 40 kg/cm² and advises contacting the factory for pressure above 40 kg/cm².

Can DLS be installed in an external chamber?

Yes. External chamber configurations are included in the DLS installation options and ordering information.

📋 Request Detailed Information

Browse More Categories

Digital Panel Meters (25) Industries (115) Multifunction Meters (18) Partnering Brands (833) PID Controllers (22) Pressure (168) Pressure Switches (262) Process Control Instruments (748) Process Controllers (33) Products (1583) Sensors (448) Solutions (115)

Related Products

Need a quote? Chat with us!