📍 201/1, Dr. Nanjappa road, Coimbatore, Tamil Nadu, India
Try: PRK5B, 50155803, retro-reflective, safety light curtain, M12 connector

Shridhan HFS series – Horizontal Magnetic Float Level Switch | ProSens Automation

● In Stock

The Shridhan HFS Series comprises Horizontal Mounting Magnetic Float Level Switches for high, low or intermediate point level switching.

Designed for tanks with inaccessible tops or bottoms and applications where the insertion depth of top-mounted models is exceeded.

Available with multiple enclosure, wetted-part, process connection, switch and pressure-temperature configurations, including external chamber installation.

✅ Genuine Shridhan product with manufacturer warranty

✅ ProSens Automation — Coimbatore, Erode & Salem

Product Description

Shridhan HFS Series – Horizontal Mounting Magnetic Float Level Switches

The Shridhan HFS Series comprises Horizontal Mounting Magnetic Float Level Switches designed for high, low or intermediate point level switching in industrial tanks and vessels.

The HFS Series is particularly suited to tanks with inaccessible tops or bottoms and applications where the insertion depth of conventional top-mounted level switches is exceeded.

The switch uses a free-moving pivoted float assembly and magnetic repulsion to operate the switching mechanism. Dual magnets are used — one in the float arm and another in the contact carrier inside the switch enclosure. A change in liquid level causes magnetic repulsion and produces a changeover of the contacts with snap action.

The magnetic transmission is glandless, which the brochure describes as eliminating a leakage path from the vessel into the switch housing. HFS switches are available in different materials, enclosures and configurations for a broad range of media and applications.

Key Features

  • Horizontal mounting magnetic float level switch.
  • High, low or intermediate point level switching.
  • Suitable for tanks with inaccessible tops or bottoms.
  • Suitable where top-mounted insertion depth is exceeded.
  • Magnetic repulsion operating principle.
  • Free-moving pivoted float assembly.
  • Glandless magnetic transmission.
  • Weather-proof, flame-proof and polypropylene enclosure options.
  • Complete SS316 construction option available.
  • External chamber option available.
  • Customization available as specified in the brochure.

How the HFS Series Works

The HFS Series operates using magnetic repulsion rather than a conventional direct mechanical transmission.

Component Function
Pivoted float assembly Moves with changes in liquid level.
Float magnet Provides the magnetic field associated with float movement.
Contact-carrier magnet Works with the float magnet through magnetic repulsion.
Switch mechanism Changes contact state with snap action as liquid level changes.

The switch enclosure is made from non-magnetic material to maintain the magnetic flux required for operation.

Installation Options

Installation Application
Internal mounting Direct installation inside the tank or vessel.
External chamber mounting Used when the switch needs to be installed outside the main vessel.
Side mounting Normal mounting arrangement for the HFS Series.
Top installation The brochure notes top installation as preferred for applications such as slurry.

External mounting can be used where space is limited or mechanical devices such as stirrers operate inside the tank. The brochure also describes external mounting for boilers and reaction kettles where isolation can assist regular servicing.

Configuration Options

Parameter Available Options
Enclosure Weather Proof IP65 / Aluminum; Flame Proof / SS304 for Group IIA, IIB; Flame Proof / SS304 for Group IIC; Polypropylene; Others
Wetted Parts SS304, SS316, SS316L, Polypropylene, Titanium, Hastelloy C276, PVDF, Others
Process Connection Multiple flange configurations, 1.5" NPT(M), 2" NPT(M), Others
Switch Type 1 SPDT, 2 SPDT, hermetically sealed 1 SPDT, hermetically sealed 1 DPDT
Float Multiple material and diameter combinations
Accessories Counter flange, counter flange with test lever, counter flange stub, chamber and others

Process Connection Options

Option Specification
Flange Sq. 92 × 92 PCD, casted flange
Flange Ø120 mm × 92 PCD
Flange Ø127 mm × 98 PCD, 1½" #150
Flange Ø152 mm × 121 PCD, 2" #150
Flange Ø152 mm × 114 PCD, 2" BS 10-E
Flange Ø190 mm × 152.4 PCD, 3" #150
Flange Ø165 mm × 127 PCD, 2½" BS 10-E
Flange Ø178 mm × 140 PCD, 2½" #150
Flange Ø230 mm × 190 PCD, 4" #150
Threaded 1.5" NPT (M)
Threaded 2" NPT (M)

Switch Options

Option Rating / Description
1 SPDT Micro Switch 250V AC / 5A
2 SPDT Micro Switch 250V AC / 5A
Hermetically Sealed Micro Switch 250V AC / 5A, 1 SPDT
Hermetically Sealed Micro Switch 250V AC / 5A, 1 DPDT *

* Consult factory.

Pressure & Temperature Configurations

Configuration Pressure / Temperature Rating
Ambient Ambient pressure & temperature
Option 2 10 kg/cm², 150°C
Option 3 10 kg/cm², 180°C
Option 4 20 kg/cm², 180°C
Option 5 40 kg/cm², 200°C
Option 6 100 kg/cm², 150°C

Float Options

Code Material Float Diameter
F1 SS304 50 mm
F2 SS304 57 mm
F3 SS316 57 mm
F4 PP 60 mm
F5 PP 53 mm
F6 SS316L 46 mm
F7 SS316L 50 mm
F8 SS316 50 mm

Accessories

Accessory Availability
No accessory Not applicable
Counter flange Available
Counter flange with test lever Available
Counter flange stub Available
Chamber Available

Where HFS Series Is Used

Application / Situation HFS Use
Tanks with inaccessible tops Horizontal mounting provides an alternative to top-mounted installation.
Tanks with inaccessible bottoms Suitable for horizontal point-level switching.
Limited insertion depth Suitable where top-mounted insertion depth is exceeded.
Boilers External mounting option is described for boiler applications.
Reaction kettles External mounting can allow isolation for servicing.
Slurry applications The brochure notes top installation as preferred for slurry.

The HFS switch can be wired to make or break electrical circuits associated with burners, heaters, motor pumps, alarms and other electrically operated devices.

Features Mentioned in the Brochure

  • Approved by CMRI for Group I, IIA and IIB applications.
  • Complete SS316 material option available.
  • Customization on request.
  • External chamber option available.

Ordering Information

The brochure provides the ordering structure HFS 1 2 3 4 5 6 7. The selection is based on enclosure, wetted parts, process connection, switch type, pressure-temperature rating, float and accessories.

Selection What to Specify
1 — Enclosure Weather-proof / flame-proof / polypropylene / other
2 — Wetted Parts SS304 / SS316 / SS316L / PP / Titanium / Hastelloy C276 / PVDF / other
3 — Process Connection Required flange or threaded connection
4 — Switch Type Required micro-switch configuration
5 — Pressure & Temperature Required pressure-temperature rating
6 — Float Float material and diameter
7 — Accessories Counter flange, test lever, stub, chamber or other accessory

Example Configuration

The brochure provides HFS W 2 1 1 2 F3 as an example ordering configuration. Actual selection should be made according to the customer's tank, liquid, process connection, switching and pressure-temperature requirements.

What's in the Box

  • Shridhan HFS Series Horizontal Mounting Magnetic Float Level Switch
  • Configured enclosure, float and process connection as ordered
  • Selected accessories, where included in the order
  • Product documentation, as applicable

Buy Shridhan HFS Series from ProSens Automation

ProSens Automation supplies Shridhan Automation level switches for industrial liquid-level applications across Coimbatore, Erode, Salem and locations across India.

For correct HFS selection, share the tank arrangement, liquid details, mounting position, required switching point, process connection, pressure, temperature and electrical switching requirements.

Need a quotation? Contact ProSens Automation for price, availability, technical specifications and application compatibility.

FAQ

What is the Shridhan HFS Series?

The HFS Series is a Horizontal Mounting Magnetic Float Level Switch designed for high, low or intermediate point level switching.

When should I use an HFS instead of a top-mounted level switch?

The brochure specifically identifies HFS for tanks with inaccessible tops or bottoms and where the insertion depth of top-mounted models is exceeded.

How does the HFS switch operate?

It uses a pivoted float assembly and dual magnets. Changes in liquid level cause magnetic repulsion, producing snap-action switching.

Can HFS be installed outside the tank?

Yes. The brochure provides an external chamber option for installation outside the main vessel.

Is an explosion-proof version available?

Yes. The ordering information includes flame-proof SS304 enclosure options for Group IIA/IIB and Group IIC applications.

What process connections are available?

The brochure lists several flange configurations as well as 1.5" NPT(M) and 2" NPT(M), with other options available.

What pressure and temperature ratings are available?

The ordering information lists configurations from ambient pressure and temperature through ratings including 10 kg/cm² at 150°C, 20 kg/cm² at 180°C, 40 kg/cm² at 200°C and 100 kg/cm² at 150°C.

Can the HFS Series be customized?

Yes. The brochure explicitly lists customization on request.

📋 Request Detailed Information

Browse More Categories

Digital Panel Meters (25) Industries (115) Multifunction Meters (18) Partnering Brands (833) PID Controllers (22) Pressure (168) Pressure Switches (262) Process Control Instruments (748) Process Controllers (33) Products (1583) Sensors (448) Solutions (115)

Related Products