📍 201/1, Dr. Nanjappa road, Coimbatore, Tamil Nadu, India
Try: PRK5B, 50155803, retro-reflective, safety light curtain, M12 connector

Shridhan HLX series – Hydrostatic Level Transmitter | ProSens Automation

● In Stock

The Shridhan HLX Series comprises Hydrostatic Level Transmitters for continuous liquid level measurement in ventilated tanks.

The level probe uses a piezoresistive sensor with a titanium membrane and measures hydrostatic pressure to determine liquid level, with measurement unaffected by electrical medium properties or foam formation.

Available with 4-20mA, 2-wire output, optional HART and MODBUS (RS485), titanium construction and IP68 protection for water, sewage, swimming pools, ballast tanks and chloride-containing media.

✅ Genuine Shridhan product with manufacturer warranty

✅ ProSens Automation — Coimbatore, Erode & Salem

Product Description

The Shridhan HLX Series Hydrostatic Level Transmitter is designed for continuous liquid level measurement in ventilated tanks and vessels.

The HLX measures hydrostatic pressure using a piezoresistive sensor with a titanium membrane. The surrounding pressure is compensated through an integrated pressure-equalization hose inside the cable, allowing the transmitter to measure liquid level accurately in ventilated tanks.

The transmitter is designed for applications where the liquid may contain foam or where electrical properties of the medium can vary. The brochure also specifies a titanium version for high chemical resistance and a front-flush membrane arrangement for highly viscous media.

The HLX provides a 4-20mA, 2-wire output, with HART and MODBUS (RS485) available as optional communication interfaces.

Key Features

  • Continuous hydrostatic liquid level measurement
  • Piezoresistive silicon sensor with titanium membrane
  • Measuring ranges from 100 mbar relative pressure
  • Absolute pressure versions available from 600 mbar
  • Titanium construction for high chemical resistance
  • Front-flush membrane for harsh and highly viscous media
  • Integrated pressure compensation hose
  • 4-20mA, 2-wire output
  • Optional HART communication
  • Optional MODBUS (RS485) communication
  • Reverse-polarity protection
  • IP68 protection
  • Cable length according to customer preference
  • Suitable for chloride-containing media
  • Wide range of accessories for installation

These features are stated in the HLX brochure's application, customer-benefit and special-feature sections. :contentReference[oaicite:1]{index=1}

How the HLX Hydrostatic Level Transmitter Works

The HLX is installed vertically and hangs from its cable inside the tank. The sensor detects the hydrostatic pressure produced by the liquid column above the measuring membrane.

Because the cable contains an integrated pressure-equalization hose, the transmitter can compensate for surrounding atmospheric pressure while measuring the hydrostatic pressure generated by the liquid.

The piezoresistive sensor converts the pressure into an electrical signal, which is provided as a standardized 4-20mA, 2-wire output.

Component Function
Titanium Measuring Membrane Transfers hydrostatic pressure from the liquid to the sensing element.
Piezoresistive Sensor Measures the applied hydrostatic pressure.
Pressure Compensation Hose Compensates for surrounding pressure through the integrated cable.
Electronics Converts the measured pressure into the standardized current output.

The brochure specifies the piezoresistive sensor, titanium membrane, synthetic-oil pressure transfer medium and vertical/hanging installation. :contentReference[oaicite:2]{index=2}

General Technical Specifications

Parameter Specification
Measuring Principle Piezoresistive sensor with titanium membrane
Pressure Transfer Medium Synthetic oil
Admissible Load Changes >10 million, 0% to 100% measuring range
Reference Conditions According to DIN 16086 and DIN 61298
Mounting Vertical / hanging from the cable
Output 4-20mA, 2-wire
Communication HART & MODBUS (RS485) optional
Step Response 2 ms
Power Supply DC 16-28V, nominal 24V
Maximum Current Consumption 23 mA
Electrical Circuit SELV
Reverse Voltage Protection Yes

These specifications are taken from the HLX technical-data section on page 3. :contentReference[oaicite:3]{index=3} :contentReference[oaicite:4]{index=4}

Cable Specifications

Parameter Specification
Cable Type 6-core, shielded cable with integrated pressure compensation hose
Cable Size AWG 24 with ferrules
Outer Sheath FEP
Compensation Hose PA
Colour Black
Outer Diameter Approximately 8.4 mm
Conductor Cross Section 0.25 mm²
Minimum Bending Radius — Moving 140 mm
Minimum Bending Radius — Fixed 70 mm
Tensile Force 4000 N
Mass Approximately 90 g/m
Admissible Temperature -40 to +70°C, depending on the medium
UV Resistance Yes, according to DIN ISO 4892-2

The cable specifications are provided on page 3 of the brochure. :contentReference[oaicite:5]{index=5}

Mechanical Construction

Component Material / Specification
Protective Cap PVC
Process Connection Titanium Grade 2
Measuring Membrane Titanium Grade 2
Case Titanium Grade 2
Shrink Tubing Polyolefin
Mass without Cable 109 g
Probe Diameter 27 mm

The mechanical construction and dimensions are shown on pages 4 and 5. The page 5 drawing also identifies the cable length as customer-selectable. :contentReference[oaicite:6]{index=6} :contentReference[oaicite:7]{index=7}

Measuring Range & Accuracy

Measuring Range Pressure Type Linearity Accuracy at 20°C Overload Burst Pressure
0–0.1 bar Relative 0.2% MSP 1.2% MSP 0.3 bar 0.4 bar
0–0.16 bar Relative 0.2% MSP 0.8% MSP 0.48 bar 0.64 bar
0–0.25 bar Relative 0.2% MSP 0.8% MSP 0.75 bar 1 bar
0–0.4 bar Relative 0.2% MSP 0.7% MSP 1.2 bar 1.6 bar
0–0.6 bar Relative / Absolute 0.2% MSP 0.7% MSP 1.8 bar 2.4 bar
0–1 bar Relative / Absolute 0.2% MSP 0.6% MSP 3 bar 4 bar
0–1.6 bar Relative / Absolute 0.25% MSP 0.5% MSP 4.8 bar 6.4 bar
0–2.5 bar Relative / Absolute 0.25% MSP 0.5% MSP 7.5 bar 10 bar
0–4 bar Relative / Absolute 0.25% MSP 0.5% MSP 12 bar 16 bar
0–6 bar Relative / Absolute 0.25% MSP 0.5% MSP 18 bar 24 bar
0–10 bar Relative / Absolute 0.25% MSP 0.5% MSP 30 bar 40 bar

The measuring-range table is provided on page 4 of the brochure. MSP means measuring span, as defined in the notes on page 5. :contentReference[oaicite:8]{index=8} :contentReference[oaicite:9]{index=9}

Environmental & Protection Specifications

Parameter Specification
Medium Temperature 0 to 50°C
Storage Temperature -20 to +70°C, dry
Protection Type IP68
EMC Interference Emission Class B
EMC Interference Immunity Industrial requirements
Ignition Protection Type Gb T4: -40 to +85°C; T5: -40 to +70°C; T6: -40 to +55°C ambient
Ignition Protection Type Db T100°C: -40 to +85°C; T85°C: -40 to +70°C; T70°C: -40 to +55°C ambient

The environmental data and ignition-protection temperature classes are specified on page 4. :contentReference[oaicite:10]{index=10}

Installation & Accessories

The HLX is designed for vertical installation by hanging from the cable. The brochure also provides accessory arrangements for installation and cable management.

Accessory Purpose / Brochure Reference
Cable Clamp Shown as an installation accessory for the level-probe cable.
Terminal Box with Pressure Compensation Shown as an accessory arrangement incorporating pressure compensation.
Sealing Screw Shown as an accessory on page 6.

The accessory dimensions are illustrated on page 6 of the brochure. :contentReference[oaicite:11]{index=11}

Where HLX Series Is Used

Application Typical Use
Pumping Stations Continuous liquid level measurement and level control.
Water Treatment Level monitoring in water-treatment tanks and systems.
Shipbuilding / Ballast Water Liquid level measurement in ballast water tanks.
Sewage Sector Continuous level measurement in sewage applications.
Swimming Pools Level measurement in splash-water containers.
Chloride-Containing Media Applications requiring resistance to chloride-containing liquids.
Highly Viscous Media Front-flush membrane configuration for harsh and highly viscous media.

These applications are explicitly listed in the HLX brochure. :contentReference[oaicite:12]{index=12}

Electrical Connection

The standard electrical configuration is a 4-20mA, 2-wire connection with a DC 24V rated supply. The connection diagram on page 7 shows the level probe connected through a power supply to controller, display and recorder equipment.

Connection Cable Assignment
+ Supply / Signal White
0V / Signal Gray
Shielding Black

The brochure specifically cautions that the electrical connection should be performed according to the installation instructions or operating manual and that connected devices should be grounded to the same potential. :contentReference[oaicite:13]{index=13}

What's in the Box

  • Shridhan HLX Hydrostatic Level Transmitter / level probe
  • Integrated 6-core shielded cable with pressure compensation hose
  • Selected cable length according to the ordered configuration

The brochure does not provide a separate standard packing list. Accessories such as the cable clamp, terminal box with pressure compensation and sealing screw are shown separately and should therefore be confirmed with the selected quotation.

Buy Shridhan HLX Hydrostatic Level Transmitters from ProSens Automation

The Shridhan HLX Series is available through ProSens Automation for continuous liquid level measurement in water, sewage, pumping, swimming-pool, shipbuilding and other compatible applications.

For correct selection, share the tank depth, liquid, required measuring range, pressure type, temperature, specific application, cable length and communication requirement.

ProSens Automation — Coimbatore, Erode & Salem
Shipping available across India.

FAQ

What is the Shridhan HLX Series?

The HLX Series is a hydrostatic level transmitter designed for continuous liquid level measurement in ventilated tanks.

How does the HLX measure liquid level?

The HLX measures the hydrostatic pressure generated by the liquid column using a piezoresistive sensor with a titanium membrane. The pressure is converted into a standardized 4-20mA output.

What output does the HLX provide?

The standard output is 4-20mA, 2-wire. HART and MODBUS (RS485) are specified as optional communication interfaces.

What power supply is required?

The basic type uses DC 16-28V, with a nominal supply voltage of 24V.

What is the minimum measuring range?

The brochure lists a measuring range of 0-0.1 bar relative pressure as the lowest specified range.

What is the maximum measuring range?

The brochure lists 0-10 bar relative/absolute pressure as the highest specified measuring range.

Can HLX measure in chloride-containing liquids?

Yes. The brochure specifically describes the level probe as designed for liquids containing chlorides and lists shipbuilding, swimming pools, water and sewage management among the applications.

Can HLX be used in sewage applications?

Yes. The sewage sector is explicitly listed as an application.

Can HLX be used in highly viscous media?

Yes. The brochure specifies a front-flush membrane configuration as an alternative for highly viscous media.

Is the HLX suitable for hazardous areas?

The brochure provides ignition-protection specifications for Gb and Db configurations and states that approvals are needed for particular shipbuilding requirements and explosion protection.

What is the protection rating?

The HLX technical data specifies IP68 protection.

Does the HLX cable compensate for atmospheric pressure?

Yes. The cable incorporates an integrated pressure-equalization hose for surrounding-pressure compensation.

Can the cable length be customized?

Yes. The dimensions section states that cable length is according to customer preference.

📋 Request Detailed Information