📍 201/1, Dr. Nanjappa road, Coimbatore, Tamil Nadu, India
Try: PRK5B, 50155803, retro-reflective, safety light curtain, M12 connector

Shridhan MLS series – External Chamber Level Switch | ProSens Automation

● In Stock

The Shridhan MLS Series comprises External Chamber Level Switches designed for reliable liquid level measurement and control in industrial vessels.

The external chamber arrangement provides smooth level control, including applications where vessel turbulence, process isolation, high pressure, high temperature or corrosive conditions need to be considered.

Available with adjustable micro-switch mechanisms, SS304 or SS316 float and stem, multiple chamber materials, process connections and up to three adjustable switch mechanisms.

✅ Genuine Shridhan product with manufacturer warranty

✅ ProSens Automation — Coimbatore, Erode & Salem

Product Description

Shridhan HFS Series – Horizontal Mounting Magnetic Float Level Switches

Shridhan MLS Series – External Chamber Level Switches

The Shridhan MLS Series comprises External Chamber Level Switches designed for liquid level measurement and control where the level switch is installed in a chamber outside the main process vessel.

The external chamber arrangement allows the level switch to operate in a controlled chamber rather than directly inside the main vessel. The brochure describes this arrangement as providing smooth level control irrespective of turbulence in the process vessel and helping prevent accidental damage to the switch during vessel shutdown or maintenance.

Chamber arrangements are also described for applications requiring process isolation, high-pressure or high-temperature operation, corrosive service and onshore/offshore installations.

Key Features

  • External chamber level switch construction.
  • Designed for liquid level measurement and control.
  • Suitable for level control independent of vessel turbulence.
  • Provides process isolation through external chamber installation.
  • Adjustable micro-switch mechanism.
  • Bi-stable switch action.
  • Up to three adjustable switch mechanisms.
  • SS304 or SS316 float and stem options.
  • Multiple chamber material options.
  • Multiple process connection options.
  • High-temperature configurations available.
  • High-pressure configurations available.

How the MLS Series Works

The MLS Series uses an external chamber connected to the process vessel. The liquid level inside the chamber follows the process level, allowing the float and stem assembly to sense the level without placing the complete switch arrangement directly inside the main vessel.

As the liquid level changes, the float moves and operates the adjustable micro-switch mechanism. The switch is specified as bi-stable and can be configured with up to three adjustable switch mechanisms.

Component Function
External chamber Provides a separate chamber connected to the process vessel for level sensing.
Float & stem Detects changes in liquid level within the chamber.
Switch mechanism Adjustable micro-switch mechanism for level switching.
Process connections Connect the chamber to the process vessel.

Why Use an External Chamber?

Application Requirement MLS Chamber Arrangement
Process turbulence Provides smooth level control irrespective of turbulence in the main process vessel.
Maintenance Can help prevent accidental damage to the switch during vessel shutdown or maintenance.
Process isolation External chamber arrangement supports applications requiring isolation of the process.
High pressure The brochure provides configurations for high-pressure applications.
High temperature Configurations are available for temperatures up to 400°C with cooling fins.
Corrosive applications Multiple material options are provided to suit different environmental conditions.

General Specifications

Specification MLS Series
Enclosure Cast Aluminium, Weather Proof IP66
Conduit Connection Brass ¾" ET or ½" NPT
Switch Mechanism Adjustable micro switch, 5A, 230VAC (SPDT)
Switch Action Bi-stable
Number of Switch Mechanisms Maximum three, adjustable
Control Range 150 mm approximately
Operating Differential 25 ± 5 mm
Float & Stem SS304 or SS316
Float Size Ø50 × 150 mm
C-C Distance 300–1000 mm *
Vent ½" Plug / Flanged
Minimum Liquid Specific Gravity 0.8

* Consult factory for long C-C distances.

Chamber Material Options

Configuration Chamber Material
IBR CS (IBR grade) / Custom
Non-IBR CS / SS304 / SS316

Process Connection Options

Application / Configuration Process Connection
IBR Flanged, 25 NB, BS 10-E or ANSI standard
Non-IBR Flanged, 25 NB or ANSI standard

Drain & Float / Stem Options

Component Options
Float & Stem SS304 / SS316
Float Size Ø50 × 150 mm
Drain 1½" BSP Plug / Others

Temperature & Pressure Ratings

Specification Rating
Maximum Temperature — without cooling fins 200°C
Maximum Temperature — with cooling fins 400°C
Test Pressure Up to 50 kg/cm²

Installation Options

Installation Arrangement Description
External chamber Level switch installed in an external chamber connected to the main vessel.
Process connection Chamber connected to the process through the specified process connections.
Drain connection Provided for draining the chamber as specified in the configuration.
Vent ½" plug or flanged option.

Where MLS Series Is Used

Application Requirement MLS Application
Level measurement External chamber level measurement.
Level control Adjustable switching points for liquid level control.
Process isolation External chamber arrangement for applications requiring isolation.
High-pressure applications Available with high-pressure chamber configurations.
High-temperature applications Configurations up to 200°C without cooling fins or 400°C with cooling fins.
Corrosive applications Multiple material options are available to suit different environmental conditions.
Onshore / offshore installations The brochure specifically lists onshore/offshore installations among chamber applications.

Ordering Information

The brochure provides the ordering structure MLS 1 2 3 4 5 6. Selection covers the approval, process connection, chamber configuration, float and stem, drain and associated configuration requirements.

Selection Parameter Options / Information
Approval None / IBR
Process Connection 1" NB ANSI 150#, 1.5" NB ANSI 150#, Others
Chamber Without, CS (IBR), CS (Non-IBR), SS304 (Non-IBR), SS316 (Non-IBR), Others
Float & Stem SS304, SS316, Others
Drain 1½" BSP Plug, Others
Switches Maximum three adjustable switch mechanisms

What's in the Box

  • Shridhan MLS Series External Chamber Level Switch
  • Configured chamber, float/stem and process connections as ordered
  • Selected drain and vent arrangement, where applicable
  • Product documentation, as applicable

Buy Shridhan MLS Series from ProSens Automation

ProSens Automation supplies Shridhan Automation level switches for industrial liquid-level applications across Coimbatore, Erode, Salem and locations across India.

For correct MLS selection, share the vessel/process details, liquid specific gravity, required level points, chamber C-C distance, pressure, temperature, process connection, chamber material and required approval.

Need a quotation? Contact ProSens Automation for price, availability, technical specifications and application compatibility.

FAQ

What is the Shridhan MLS Series?

The MLS Series is an External Chamber Level Switch designed for liquid level measurement and control.

Why is an external chamber used?

The brochure describes external chambers as useful where smooth level control is required despite vessel turbulence, or where process isolation, high pressure, high temperature, corrosive service or maintenance considerations apply.

How many switch mechanisms can the MLS have?

The general specifications state a maximum of three adjustable switch mechanisms.

What type of switch is used?

The brochure specifies an adjustable micro switch rated at 5A, 230VAC (SPDT), with bi-stable switch action.

What float and stem materials are available?

SS304 and SS316 are specified in the MLS general specifications and ordering information.

What is the maximum temperature?

The brochure specifies up to 200°C without cooling fins and up to 400°C with cooling fins.

What is the maximum test pressure?

The specified test pressure is up to 50 kg/cm².

What information is needed to select an MLS?

Provide the required approval, process connection, chamber material, float/stem material, drain requirement, chamber C-C distance, operating temperature, operating pressure, liquid specific gravity and required switching levels.

📋 Request Detailed Information

Browse More Categories

Digital Panel Meters (25) Industries (115) Multifunction Meters (18) Partnering Brands (833) PID Controllers (22) Pressure (168) Pressure Switches (262) Process Control Instruments (748) Process Controllers (33) Products (1583) Sensors (448) Solutions (115)

Related Products

Need a quote? Chat with us!