The Shridhan MLS Series comprises External Chamber Level Switches designed for reliable liquid level measurement and control in industrial vessels.
The external chamber arrangement provides smooth level control, including applications where vessel turbulence, process isolation, high pressure, high temperature or corrosive conditions need to be considered.
Available with adjustable micro-switch mechanisms, SS304 or SS316 float and stem, multiple chamber materials, process connections and up to three adjustable switch mechanisms.
✅ Genuine Shridhan product with manufacturer warranty
✅ ProSens Automation — Coimbatore, Erode & Salem
The Shridhan MLS Series comprises External Chamber Level Switches designed for liquid level measurement and control where the level switch is installed in a chamber outside the main process vessel.
The external chamber arrangement allows the level switch to operate in a controlled chamber rather than directly inside the main vessel. The brochure describes this arrangement as providing smooth level control irrespective of turbulence in the process vessel and helping prevent accidental damage to the switch during vessel shutdown or maintenance.
Chamber arrangements are also described for applications requiring process isolation, high-pressure or high-temperature operation, corrosive service and onshore/offshore installations.
The MLS Series uses an external chamber connected to the process vessel. The liquid level inside the chamber follows the process level, allowing the float and stem assembly to sense the level without placing the complete switch arrangement directly inside the main vessel.
As the liquid level changes, the float moves and operates the adjustable micro-switch mechanism. The switch is specified as bi-stable and can be configured with up to three adjustable switch mechanisms.
| Component | Function |
|---|---|
| External chamber | Provides a separate chamber connected to the process vessel for level sensing. |
| Float & stem | Detects changes in liquid level within the chamber. |
| Switch mechanism | Adjustable micro-switch mechanism for level switching. |
| Process connections | Connect the chamber to the process vessel. |
| Application Requirement | MLS Chamber Arrangement |
|---|---|
| Process turbulence | Provides smooth level control irrespective of turbulence in the main process vessel. |
| Maintenance | Can help prevent accidental damage to the switch during vessel shutdown or maintenance. |
| Process isolation | External chamber arrangement supports applications requiring isolation of the process. |
| High pressure | The brochure provides configurations for high-pressure applications. |
| High temperature | Configurations are available for temperatures up to 400°C with cooling fins. |
| Corrosive applications | Multiple material options are provided to suit different environmental conditions. |
| Specification | MLS Series |
|---|---|
| Enclosure | Cast Aluminium, Weather Proof IP66 |
| Conduit Connection | Brass ¾" ET or ½" NPT |
| Switch Mechanism | Adjustable micro switch, 5A, 230VAC (SPDT) |
| Switch Action | Bi-stable |
| Number of Switch Mechanisms | Maximum three, adjustable |
| Control Range | 150 mm approximately |
| Operating Differential | 25 ± 5 mm |
| Float & Stem | SS304 or SS316 |
| Float Size | Ø50 × 150 mm |
| C-C Distance | 300–1000 mm * |
| Vent | ½" Plug / Flanged |
| Minimum Liquid Specific Gravity | 0.8 |
* Consult factory for long C-C distances.
| Configuration | Chamber Material |
|---|---|
| IBR | CS (IBR grade) / Custom |
| Non-IBR | CS / SS304 / SS316 |
| Application / Configuration | Process Connection |
|---|---|
| IBR | Flanged, 25 NB, BS 10-E or ANSI standard |
| Non-IBR | Flanged, 25 NB or ANSI standard |
| Component | Options |
|---|---|
| Float & Stem | SS304 / SS316 |
| Float Size | Ø50 × 150 mm |
| Drain | 1½" BSP Plug / Others |
| Specification | Rating |
|---|---|
| Maximum Temperature — without cooling fins | 200°C |
| Maximum Temperature — with cooling fins | 400°C |
| Test Pressure | Up to 50 kg/cm² |
| Installation Arrangement | Description |
|---|---|
| External chamber | Level switch installed in an external chamber connected to the main vessel. |
| Process connection | Chamber connected to the process through the specified process connections. |
| Drain connection | Provided for draining the chamber as specified in the configuration. |
| Vent | ½" plug or flanged option. |
| Application Requirement | MLS Application |
|---|---|
| Level measurement | External chamber level measurement. |
| Level control | Adjustable switching points for liquid level control. |
| Process isolation | External chamber arrangement for applications requiring isolation. |
| High-pressure applications | Available with high-pressure chamber configurations. |
| High-temperature applications | Configurations up to 200°C without cooling fins or 400°C with cooling fins. |
| Corrosive applications | Multiple material options are available to suit different environmental conditions. |
| Onshore / offshore installations | The brochure specifically lists onshore/offshore installations among chamber applications. |
The brochure provides the ordering structure MLS 1 2 3 4 5 6. Selection covers the approval, process connection, chamber configuration, float and stem, drain and associated configuration requirements.
| Selection Parameter | Options / Information |
|---|---|
| Approval | None / IBR |
| Process Connection | 1" NB ANSI 150#, 1.5" NB ANSI 150#, Others |
| Chamber | Without, CS (IBR), CS (Non-IBR), SS304 (Non-IBR), SS316 (Non-IBR), Others |
| Float & Stem | SS304, SS316, Others |
| Drain | 1½" BSP Plug, Others |
| Switches | Maximum three adjustable switch mechanisms |
ProSens Automation supplies Shridhan Automation level switches for industrial liquid-level applications across Coimbatore, Erode, Salem and locations across India.
For correct MLS selection, share the vessel/process details, liquid specific gravity, required level points, chamber C-C distance, pressure, temperature, process connection, chamber material and required approval.
Need a quotation? Contact ProSens Automation for price, availability, technical specifications and application compatibility.
What is the Shridhan MLS Series?
The MLS Series is an External Chamber Level Switch designed for liquid level measurement and control.
Why is an external chamber used?
The brochure describes external chambers as useful where smooth level control is required despite vessel turbulence, or where process isolation, high pressure, high temperature, corrosive service or maintenance considerations apply.
How many switch mechanisms can the MLS have?
The general specifications state a maximum of three adjustable switch mechanisms.
What type of switch is used?
The brochure specifies an adjustable micro switch rated at 5A, 230VAC (SPDT), with bi-stable switch action.
What float and stem materials are available?
SS304 and SS316 are specified in the MLS general specifications and ordering information.
What is the maximum temperature?
The brochure specifies up to 200°C without cooling fins and up to 400°C with cooling fins.
What is the maximum test pressure?
The specified test pressure is up to 50 kg/cm².
What information is needed to select an MLS?
Provide the required approval, process connection, chamber material, float/stem material, drain requirement, chamber C-C distance, operating temperature, operating pressure, liquid specific gravity and required switching levels.